Description
The MCWlaser brand laser tubes with advanced production processes, superior performance,stringent testing standards, high-quality materials, and universal compatibility. and can work with popular brand laser engraver cutting & engraving machine.It can replace popular brand CO2 laser tube, and be compatible with popular brand power supply.Great replacement for the same power or same legth laser tube.
Our laser tubes undergo a variety of rigorous tests before being sent out.
1. Maximum Power Output Test
2. Minimum Triggering Current Test
3. Power Output Stability Test
4. TEM₀₀ Laser Spot Test
If you seek a laser tube that delivers precision, durability, and versatility, MCWlaser should be your top choice. Embrace the cutting-edge technology offered by MCWlaser brand laser tubes and take your laser cutting and engraving projects to new heights of excellence.

Parameter
| Rated Power | 40W | 50W | 60W | 60W | 80W | 90W | 100W | 130W | 150W | 180W |
| Model | M40 | M50 | M60 | M60H | M80L | M80 | M100 | M130 | M150 | M180 |
| Length | 700mm | 850mm | 1000mm | 1250mm | 1600mm | 1250mm | 1450mm | 1650mm | 1800mm | 2000mm |
| Actual Power | 40~45W | 50~55W | 60W | 60~80W | 80~100W | 80~100W | 100~130W | 130~150W | 150~180W | 180~200W |
| Catalyst | ✓ | |||||||||
| Mode | TEM₀₀ | |||||||||
| Operating Current(mA) | 20 | 20 | 25 | 25 | 25 | 25 | 30 | 30 | 30 | 35 |
| Input Voltage(V) | AC 90-120V/200-240V | |||||||||
| Operating Voltage (kV) | 10 | 10 | 12 | 12 | 18 | 18 | 20 | 24 | 25 | 25 |
| Triggering Voltage (kV) | 20 | 23 | 25 | 25 | 26 | 26 | 26 | 28 | 30 | 35 |
| Outer Diameter(mm) | Φ50±2 | Φ55±2 | Φ55±2 | Φ55±2 | Φ60±2 | Φ80±2 | Φ80±2 | Φ80±2 | Φ80±2 | Φ80±2 |
| Service Life (hours) | 2000~3000 | 3000~4000 | 3000~4000 | 5000~6000 | 6000~8000 | 6000~8000 | 8000 | 8000 | 8000 | 8000 |
| Wavelength(nm) | 10600 | |||||||||
| Warranty Period | 3 months | 3 months | 6 months | 10 months | 10 months | 10 months | 10 months | 10 months | 10 months | 10 months |
Product Detail
lnstallation

Installation Tips:
1.Laser tube must be placed horizontally.It is made of glass and is fragile. Therefore, be careful when installing and using it.
2.Determine the positive and negative poles of the laser tube. (metal terminal is negative)
3.Connect the positive and negative terminals to the wires of the machine.
4.Connect the cooling water pipe. The inlet water tube is below, and the outlet water tube is above. Must be low in high out.
5.Use the laser and test switch on the machine to adjust the optical path, so that the laser point enters from the middle of the entrance hole of the laser head, and then adjust the vertical optical path. (If the battery is weak, try wiping the lens first.)
Packing

40W,50W,60W,80W laser tube package in carton case.
100W.130W,150W laser tube package in wooden cace.
NOTE:We insure the tube when ship, if there is any broken in transport, we will send the new one free again depend on the broken photos and damage report from courier.
If you find that the laser tube is broken after receiving it. Please contact us immediately. We will reissue a new replacement laser tube for you.
Maintenance
1.Always confirm optimal water circulation before turning on the machine.
2.Keep water temperature between 15℃-30℃, make sure the water temperature is similar to the environment temperature.
3.Keep the high-voltage electrode clean, dust-free, and dry.
4.Make sure that the reflective mirrors and lenses are clean; replace if any damage or wear is found.
5.Cooling Water Replacement Schedule:
*Summer: Every 2 weeks minimum (turn on air conditioning if room temperature is too high to ensure stable performance).
*Winter: Every 4 weeks minimum (use antifreeze to protect the chiller from freezing if necessary).
GET IT TOUCH
You can contact our head-office directly,also you can contact our agent which is near you.Of course,free live-chat is available and you can get help immediately.
Related Questions and Answers
Several indicators of high-quality laser tubes.
The product quality of laser tubes mainly depends on laser power, spot quality, stability and service life.
How to maintain the service life of laser tubes?
1). Matching power supply, appropriate working current, and good water cooling
2). Current setting and laser tube life
The appropriate current will not only keep your laser tube in a stable processing state, but also make the service life of the laser tube longer.
Rated Power Operating Current
40–50W ≤20mA
60-90W ≤25mA
100-150W ≤30mA
180W ≤35mA
3) Laser tube and power supply
Always match the laser tube with its specified power supply. Avoid blindly increasing the current or using a higher-power supply. Excessive current overburdens the cooling system, accelerates gas depletion, speeds up tube aging, and drastically reduces its service life.
Cooling water type
It is recommended to use deionized water or distilled water as the cooling water type. If tap water is used as cooling water for a long time, impurities in the laser water pipe will adhere and turn black, and even affect the water flow rate.
Precautions when connecting to water cooling
Pay attention to the order of the laser tubes. Make sure to turn on the cold water before turning on the laser power. Otherwise, the laser tube will become hot and break, making it unusable. In addition, make sure that the water pipe is full of water and there are large bubbles before turning on the laser power. There are bubbles in the water pipe, that is, air has entered, and with the increase in temperature, it is easy to cause the laser tube to burst; the return pipe of the cooling water is also It should be lower than the water surface, otherwise the filling may not be full next time; the water flow rate should be controlled at 2L-4L/min.
Precautions when using laser tubes
a. It is necessary to ensure the operating environment of the laser processing equipment, and the power supply voltage must be kept stable. If the voltage fluctuation is too large, configure a regulated power supply;
b. The laser processing equipment must be placed stably and cannot work in an environment with large vibrations or moisture (humidity can easily cause high-pressure sparks);
c. The laser current should not be too large, and the light intensity should be reduced as much as possible to meet the processing requirements and speed;
d. It is necessary to ensure that the laser tube has enough circulating water (temperature between 5-25°C), clean and free of debris, and replace the circulating water regularly, preferably deionized water or distilled water;
e. Finally, wipe the focusing lens from time to time to keep it clean.
Precautions for the high-voltage end part
a. Avoid ignition of the high-voltage terminal electrode, avoid accumulation of dust and metal near the high-voltage terminal, keep the high-voltage terminal dry, remove all conductive and flammable items, and keep them as far away from the metal cover of the machine as possible.
b. Check the sealing effect of the high-voltage end. After putting on the high-voltage cap, fill and seal with insulating glue or glass glue.
Precautions for current setting part
During testing and operation, the maximum current used for normal cutting of all models is 35mA. It is recommended to use a current of 20-30mA (increase the current by 3-5mA when the room temperature is lower than 15 degrees). Excessive current will increase the gas consumption rate and reduce the laser tube's performance. Lifespan is reduced.
Dust removal
Please note during work that smoke will inevitably splash onto the output surface during work. It is best to install a smoke removal device and wipe the lens regularly. Use a cotton swab specially designed for the lens dipped in absolute ethanol to wipe it.
Potential Reasons for Laser Tube Ignition Failure
1. Faulty Water Level/Flow Switch.
2. The high-voltage cable is broken or disconnected.
3. The laser tube is cracked, burnt out, or has lost its gas mixture.
4. The water pump is non-functional, or the water hoses are blocked/kinked.
5. The water protection interlock wire is broken or has poor contact.
6. The laser power supply module has failed.
7. Power & Control System Faults: poor contact of the protection circuit, power input voltage below 220V (below 110V in the US), no control signal input, or damaged motion control board.
The laser tube produces weak light and insufficient power
a. The laser tube is burned out or the laser tube light fails;
b. Reflectors and lenses need to be replaced;
c. Dust adheres to the front lens of the laser tube, causing the lens to burn;
c. The optical path of the laser tube is incorrect;
d. The materials processed are incorrect (less than 60W is generally used for engraving, and above 60W is used for cutting. Laser tubes with different powers cut different materials);
e. The tube has been used for too long, and the power of the laser tube is normally attenuated (not covered by the warranty).
Flash Sale - Lowest Prices & Discounted Prices
Recently viewed products
MCWlaser provides you with professional equipment and accessories
Please View FAQ Here
You are welcome to contact us anytime via our live chat or info@mcwlaser.com
What about the shipping method and time?
By Expedited Shipping (by DHL/Fedex/UPS/DPD), door-to-door service.
1. General products,
CN Warehouse: 5-9 Business Days
UAS Warehouse: 3-5 Business Days
EU Warehouse:5-7 Business Days
2. Customized products (Only Support Shippment From China Warehouse)
The average period of production: 5-6 Business Days
Shipping: 5-9 Business Days
(Notification: Customs clearance inspections may cause delays of 2-3 days in logistics)1. General products
By Sea or Air to sea or airport (door-to-door service is optional)
It is for larger cargo.
The delivery time depends on the detailed shipping address, please check the exact time and cost with us.
What about the Customs Duty and VAT or Tax?
1.If your order was shipped from China,the price doesn't include the import tariff duty, tax, or VAT.
The tariff duty, tax or VAT depend on local law and policy in difference country. The buyer needs to cover the cost.
2.If your order was shipped locally, such as from US ,AU or Europe,the price includes the duty,tax or VAT. The buyer don't need to pay customs duty, tax or VAT.
3 .Part of products in EU and US support PICK UP ON SITE Please check with us about the detail if you need.
If you can provide the invoice?
Yes,if you need the invoice,please contact with service@mcwlaser.com
What is your product warranty like?
All customer support services and policies will be only applied to orders on
https://www.mcwlaser.net/
https://www.mcwlaser.com/
MCWlaser Amazon Store
If your products are not purchased from our official website or our Amazon Store, but purchased through another third-party platform, we will not be responsible for your order.
Please view our detailed warranty instructions: https://www.mcwlaser.net/pages/warranty
If you have any questions, please contact us:
Email: info@mcwlaser.com
Whatsapp/Wechat: 0086 18121236578
I failed to process the payment via credit card, what should I do?
If you are having difficulty processing payment via credit card, there are a few steps you can take:
- Contact your credit card company: Verify with your credit card company whether the amount exceeds your spending limit and ensure that all payment activity is being authorized by you. It's also possible that your credit card company is experiencing technical difficulties or maintenance, which is preventing the payment from going through.
- Contact the merchant: In this case, you should contact the merchant (in this case, info@mcwlaser.com) immediately to inform them of the problem. The merchant can check if there are any issues on their end, and help you troubleshoot the problem.
- Use an alternative payment method: If the problem persists, you may want to consider using an alternative payment method, such as PayPal or bank transfer.
Remember to always exercise caution when making online purchases and to protect your personal and financial information.